Skip to content

Settings

The panel to the left of an element's diagram has three tabs: System, Axes and Display. Each section can be folded away, and the app remembers which ones are open. Every change can be undone and is saved with the session.

System

The System tabThe System tab

Element

Setting Does
System The element to calculate
Model Fixed activity gives every dissolved species the same activity, as in Pourbaix's atlas. Mass balance (closed total metal) shares a fixed total amount of metal between the dissolved species and at most one solid
Overlay Draws the boundaries of a second element under the same conditions, as dashed lines with names in italics

Iron with nickel as an overlayIron with nickel as an overlay

Metal concentration

Setting Does
Unit log₁₀ (mol/L), mol/L, ppm (mg of metal per litre) or wt %
Value The concentration in that unit. In the fixed-activity model it sets the activity of each dissolved species. In the mass-balance model it is the total metal
Solution density Used to convert weight percent to molarity (kg/L)

The line under the value gives the molarity and the log₁₀ activity.

Water

A water composition sets the ligands, the ionic strength and the probe pH in one step.

Composition Ligands Ionic strength Probe pH
Pure water None 0 Unchanged
Seawater (S = 35) Chloride, sulfate, bromide, carbonate, fluoride 0.723 mol/L 8.1
River water (world average) Carbonate, sulfate, chloride, nitrate 0.0021 mol/L Unchanged
Simulated body fluid Chloride, carbonate, phosphate, sulfate 0.161 mol/L 7.40
Saline, 0.9 % NaCl Chloride 0.154 mol/L Unchanged

The note under the list gives the source of each composition. If you change a ligand afterwards, the list shows Custom. The ionic strength of seawater is above the limit of the Davies equation (0.1 mol/L), so the app does not apply it there.

Silver in seawaterSilver in seawater

Temperature

The temperature can be set from 0 to 100 °C. The data are for 25 °C. At other temperatures, each Gibbs energy is extrapolated with its entropy of formation, assuming the formation enthalpy and entropy stay constant. Species without entropy data, and all ligand species, are left out away from 25 °C, and the context bar counts them. Temperature trends describes the method and its error estimate.

Activities

Setting Does
Davies activity coefficients (mass balance) Corrects the activities of dissolved ions for their charge, using the Davies equation at the ionic strength below. It is valid up to about 0.1 mol/L
Ionic strength 0 to 0.1 mol/L
log₁₀ gas fugacity The fugacity of all gases relative to 1 bar

Evidence policy

Setting Does
Require a Gibbs energy for every species Normally, species without a recommended Gibbs energy are left out and listed in the Species view. With this ticked, the calculation stops instead
Fill missing solid Gibbs values with labelled MP 300 K estimates Uses the stored Materials Project estimates for the solids that are terminal evidence gaps. These species are labelled in the results

Ligands

Use ligand reservoirs turns all ligands on or off at once and keeps their individual settings. The periodic table has the same switch. Below it, each ligand that forms complexes with the element has its own row:

Control Does
Checkbox Includes the ligand and its complexes
Free activity (log₁₀ a) Holds the free ligand at this activity
Total unbound pool (mol/L) Holds the total unbound ligand at this concentration. With a pKa, protonation lowers the free activity at low pH

Ligands are treated as buffered reservoirs, so binding to the metal does not change their activity. “Free” means the dissolved species unbound to a metal complex. Component names use the same name-and-formula style, such as Chloride (Cl⁻), Ammonia (NH₃) and Calcium (Ca²⁺). The total unbound pool includes the protonated and unprotonated forms, HL + L; it excludes ligand bound in metal complexes and remains externally buffered.

Nitrogen gas and the graphite, selenium and tellurium solid reservoirs retain explicit reservoir names. Their direct controls show gas fugacity relative to 1 bar or solid activity, respectively; a value of zero means 1 bar or unit activity. Hover over an activity control for its explanation.

Axes

The Axes tabThe Axes tab

Setting Does
pH minimum, pH maximum The pH range, −4 to 18 (default 0 to 14)
U minimum, U maximum The potential range in V vs SHE, −4 to 4 (default −1.5 to 1.5)
pH points, U points The grid resolution, 11 to 801 points (default 281 × 301)
Default axes Goes back to the default range and resolution
Diagram axis The potential scale of the plot: SHE, RHE (depends on pH), Ag/AgCl (sat. KCl, +0.197 V), Ag/AgCl (3 M KCl, +0.210 V), SCE (sat. KCl, +0.241 V) or Hg/HgO (1 M KOH, +0.098 V)
Probe point The pH and potential (V vs SHE) of the probe. Clicking or dragging in the diagram also moves it

The calculation and the probe always use the SHE. On the RHE scale, the corners outside the calculated potential range are left empty.

Display

The Display tabThe Display tab

Diagram

Option Shows
Domain labels The species name in each region
Legend The species and their colors
Phase boundaries The lines between regions
Water stability lines The hydrogen and oxygen evolution lines
Direct plating potential (fixed activity) The potential at which the simple cation deposits as the metal, at the set activity

Uncertainty hatching (fixed activity)

With hatching on, the diagram is hatched wherever a competing species lies within k combined standard uncertainties of the stable species, with k = 1, 2 or 3. Reported ΔfG° uncertainties are used where they exist, and reference states are exact. Other species get the assumed σ, which is 2 kJ/mol by default and can be set from 0.1 to 20 kJ/mol.

Iron with uncertainty hatching at 1 σIron with uncertainty hatching at 1 σ

Blend dissolved species

With blending on, each point is colored by a mix of the species present. In the mass-balance model, the colors mix by the fractions of the dissolved species. In the fixed-activity model, the weights are proportional to exp(−(G − Gmin)/width) over the dissolved species. At a width of RT (2.48 kJ/mol) these weights equal the fractions of the mass-balance model; other widths only blend the colors. Solids keep sharp edges in both models.

Iron with the colors of dissolved species blendedIron with the colors of dissolved species blended