What can be supported now

The database has recommended Gibbs formation energies for 262 of 268 species and formation enthalpies for 130 species. Both values are present for 129 species. No single-metal system currently has paired Gibbs energy and enthalpy for every calculation-ready species.

For a species with both values at the reference temperature T0 = 298.15 K, a transparent first-order estimate is:

Delta S_f(T0) = [Delta H_f(T0) - Delta G_f(T0)] / T0
Delta G_f(T) = Delta H_f(T0) - T Delta S_f(T0)

This is the constant-enthalpy, constant-entropy model. It is equivalent to setting the heat-capacity change Delta Cp to zero. It can show the direction and rough size of a temperature trend over a modest range.

Proposed first implementation

The first temperature feature should be a clearly labelled trend tool for individual species and reactions. Every result should report:

  • the target and reference temperatures;
  • the Gibbs and enthalpy source IDs used;
  • the derived formation entropy;
  • the exact equation above;
  • the species included and excluded;
  • the label exploratory_linear_temperature_trend.

A temperature-adjusted Pourbaix diagram needs the same model for every competing species and for liquid water. It also needs temperature-aware water stability, Kw, activity coefficients, and phase-transition checks. The present coverage is too sparse for a complete system diagram. An explicit incomplete-data mode could plot preliminary trends once the water reference is added, with all omitted species listed beside the result.

Route to quantitative diagrams

  1. Add source-backed formation enthalpy for water and fill paired enthalpy gaps for each target system.
  2. Add heat-capacity functions or tabulated values and integrate Delta Cp(T).
  3. Add temperature-dependent water properties, Kw, and activity models.
  4. Record phase-transition ranges and select the stable polymorph at each temperature.
  5. Validate against published temperature-dependent Pourbaix diagrams.

The linear model remains useful as an inspectable sensitivity analysis. The heat-capacity model becomes the quantitative path once its inputs are available.